Backend, Data & Security More detail C · Industry convention Platform: Web

Load Shedding

Load shedding rejects some work as a system nears capacity. This protects useful work from extreme delay or a full crash.

See how it works
You might call it overload sheddingtraffic sheddingoverload rejection

See how it works

Original worked exampleLoad Shedding
State & recoveryLoad Sheddingcapacity signal + priority + admission gate -> admit | reject early + retry guidance
LIVE TRAFFIC1,240 req/s
1,000✓safe capacity
1,000→admitted
240×rejected early
Core traffic stays useful503
KEEP SAFEAccepted durable work is never silently discarded.RECOVERReduce rejection only after capacity returns below a safe threshold.
capacity signal + priority + admission gate -> admit | reject early + retry guidanceSRE
Load SheddingService resilience

Another example

A service can handle 1,000 requests each second. Demand reaches 1,240. It keeps important checkout traffic and quickly rejects 240 requests.

Main parts

  1. 01Capacity signal
  2. 02Admission threshold
  3. 03Request priority
  4. 04Fast rejection
  5. 05Caller guidance
  6. 06Recovery threshold

Use it when

Use it after measuring safe capacity and request priority. Reject cheaply near the edge and give callers a clear retry signal.

Do not use it when

Do not silently drop accepted durable work. Do not wait until the server is already stuck. Coordinate retries to prevent another spike.

Name used in code

capacity signal + priority + admission gate -> admit | reject early + retry guidance

Before you ship

Check contracts and invariants, authorization, and input limits. Test retries, one-time effects, timeouts, and partial failures. Verify data integrity, compatibility, monitoring, recovery, and rollback.

Request you can copy

Outcome: Design or review Load Shedding for this system while keeping data correct, secure, and easy to operate. User context: A service can handle 1,000 requests each second. Demand reaches 1,240. It keeps important checkout traffic and quickly rejects 240 requests. Technical concept or control: Load Shedding. Why it fits: Use it after measuring safe capacity and request priority. Reject cheaply near the edge and give callers a clear retry signal. Do not use it when: Do not silently drop accepted durable work. Do not wait until the server is already stuck. Coordinate retries to prevent another spike. Engineering requirements: Define inputs, outputs, contracts, and rules that must always hold. Set authorization and input checks. Define failures, timeouts, retries, one-time effects, data moves, and compatibility limits. Operations: Add useful signals and logs that hide sensitive data. Set capacity limits and write an operator guide. Test recovery and rollback. Acceptance criteria: Contract and failure-path tests pass. Data and authorization rules still hold during retries and partial failures. Check performance limits, monitoring, recovery, and rollback. Evidence and limits (evidence boundary): No single official standard controls the whole term. Its meaning may change across teams, platforms, or frameworks. Unknowns to confirm: Where the code runs, data stores, traffic shape, consistency needs, and the security boundary. Also confirm the compatibility period, service goals, and rollback limits.

Check this request

Review the current use of Load Shedding. Definition: Load shedding rejects some work as a system nears capacity. This protects useful work from extreme delay or a full crash. Release checks: Check contracts and invariants, authorization, and input limits. Test retries, one-time effects, timeouts, and partial failures. Verify data integrity, compatibility, monitoring, recovery, and rollback. Before changing code, report the evidence you found, gaps, severity, and the smallest safe fix.

C
How official is this term?

Industry convention

People often use this term at work. The listed sources may support practice or limitations. They do not define every part of the term.

No single official standard controls the whole term. Its meaning may change across teams, platforms, or frameworks.

Scope
Cross-platform overload-protection convention; Google SRE documents one operating model, not universal capacity thresholds
Document status
stable
Checked on
2026-07-30

Evidence sources & scope

Authority source + Term reference · Google SRE · stable Addressing Cascading Failures Scope: Google SRE guidance for overload protection, load shedding, and graceful degradation; not universal capacity or priority thresholds Role here: Direct term reference Source covers: canonical name, definition, semantics, implementation, usage guidance, avoidance guidance

Copy it yourself

The browser could not copy this. Select the request below and copy it yourself.